Categories

6010-RF 689 Norton Door Controls Door Closer

Images may not represent actual product and finish.

6010-RF 689 Norton Door Controls Door Closer Slide Track Arm, Pull Side Door Operator, Radio Frequency, Aluminum Painted

$3,740.21 $5,763.00
(You save $2,022.79)
SKU:
6010-RF 689

Description

6010-RF 689 Norton Door Controls Door Closer

  • Finish: 689/US28
  • Series: 6000 Series Operators
  • Type: Door Closers and Operators
  • Sub Type: Door Closer
Type Surface
Technology Electrohydraulic
Mounting Location Pull Side
Mounting Style Slide Track
Arm Type Slide Track Arm Standard
Hand Non-Handed
Degree Swing 85¼ to 110¼
Reveal Size 1/8" Maximum
Cold Weather Fluid Yes

The 6000 Series is the newest addition to the PowerMatic Family of Operators combines intelligence, reliability and superior control in one package. Designed with the user in mind, this operator features simple to use electronics, an onboard power supply and easy integration into access control systems. Designed for moderate to high traffic applications, this operator has a two-piece sub-assembly for easy installation and LCD screen for clear and accurate read-out of operator settings. Available for push or pull side mounting, the 6000 Series can be operated manually or activated via wall switches or radio frequency devices. This reliable unit ensures consistent opening and closing based on dual mode, electrohydraulic technology and is ideal for hospitals, office buildings, sports arenas or government facilities.

The 6000 Series combines intelligence, reliability and superior control in one package.

Designed for moderate to high traffic applications, this operator has a two-piece sub-assembly for easy installation and LCD screen for clear and accurate read-out of operating settings. Available for push or pull side mounting, the 6000 Series can be operated manually or activated via wall switches or radio frequency devices. This reliable unit ensures consistent opening and closing based on dual mode, electrohydraulic technology and is ideal for hospitals, office buildings, sports arenas or government facilities.

  • Door Controls (interior)(exterior) swinging door(s) shall be of rack and pinion design contained within a precision cast aluminum housing.
  • Door closing force shall be adjustable to ensure adequate closing control.
  • Door closing speed  shall be controlled by independent hydraulic adjustment valves in the sweep and latch range of the closing cycle.
  • Door Operator shall provide conventional door closer opening and closing forces unless the power operator motor is activated.
  • Door Operator opening force and speed shall be adjustable in the inverter/interface module's LCD screen to ensure adequate opening control per accessibility codes.
  • Door Operator shall have an adjustable hydraulic backcheck valve to cushion the door speed if opened violently.
  • Door Operator shall utilize the inverter/interface module's LCD screen and joystick to establish door closes and open positions.
  • [(Door Operator shall be  AUTOMATICALLY ACTIVATED by either a slight push or pull in the direction of opening swing – Push and Go.)
  • (Door Operator shall be SELECTIVELY ACTIVATED by external initiating device, i.e. wall switch, etc.)
  • (Door Operator shall be both AUTOMATICALLY ACTIVATED and SELECTIVELY ACTIVATED.)]
  • Unit shall include "E-saver" feature to automatically recognize abled body traffic and immediately trigger door to close after sensing no forces on door.
  • Unit shall have delay for motor activation, electric lock interfacing, and hold open time.
  • Units shall have SPDT relay for interfacing latch retraction exit devices or similar products and have 24VDC @ 1.3A output for connection of electric strike, lock, radio frequency receiver, etc.
  • Units shall have Vestibule sequencing input for operation of two or more units.
  • Unit shall have smoke ventilation inputs to power open doors when activated by fire or smoke alarm.
  • Unit shall have a three-position Selector Mode Switch that will permit the unit to be switched “ON” to monitor for function inputs, switched to “H/O” for indefinite hold open function or switched “OFF” which will disable function inputs allowing unit to be used as a manual door closer.
  • Unit shall be ETL tested to UL standards for automatic closing door.
  • The Unit shall be adjustable to provide compliance with the requirements of the Americans With Disabilities Act (ADA).
  • Unit shall be certified by BHMA to meet ANSI A117.1 and A156.19 requirements.
  • Unit shall meet UL, cUL, UL10C and UL10B standards.